说明:收录全球国际标准 提供单次或批量下载
ISO INTERNATIONAL STANDARD 11608-5 Second edition 2022-04 Needle-based injection systems for medical use Requirements and test methods - Part 5: Automated functions Systemes d'injection a aiguille pour usage médical - Exigences et méthodes d'essai - Partie 5: Fonctions automatisées Reference number IS0 11608-5:2022(E) ISO @ IS0 2022 IS0 11608-5:2022(E) COPYRIGHT PROTECTED DOCUMENT @IS02022 All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior written permission. Permission can be requested from either IsO at the address below orIso'smemberbodyinthecountryoftherequester. ISO copyright office CP401·Ch.deBlandonnet8 CH-1214 Vernier, Geneva Phone: +41 22 749 01 11 Email: [email protected] Website: www.iso.org Publishedin Switzerland ii @ IS0 2022 - All rights reserved IS0 11608-5:2022(E) Contents Page iv Foreword Introduction .V Scope. 1 1 2 Normative references .1 3 Terms and definitions .2 4 Requirements. 4 4.1 General requirements 4 4.2 Medicinal product preparation 5 4.3 Needle preparation 6 4.4 Needle hiding. 6 Priming. 4.5 6 Dose setting 4.6 6 4.7 Needle insertion. 6 4.8 Injection depth control. 6 4.9 Dose delivery 7 4.10 Recording of device functions 7 4.11 Needle retraction. 7 4.11.1 Completion of dose delivery 7 4.11.2 Needle retraction distance. 7 4.11.3 Communication of completion 7 4.12 Disabling the NIS-AUTO 7 Needle shielding 4.13 8 4.13.1 General 8 4.13.21 Needle shielding before injection 8 Needle shielding after injection. 4.13.3 8 4.14 Needle removal from the NIS-AUTO 8 5 Test methods. .8 5.1 General. 8 5.2 Test conditions. 9 5.3 Actuation 9 5.4 Medicinal product preparation 9 5.5 Needle inspection 9 5.6 Needle hiding 9 5.7 Priming.... 10 5.8 Needle extension 10 5.9 Injection time. 10 5.10 Dose accuracy. 11 5.11 Retracted position. 11 5.12 Disabling the NIS-AUTO 11 Needle shielding. 5.13 11 5.13.1 Needle shielding before and after injection 11 5.13.2 Needle shielding after free fall. 11 .11 6 Information supplied with the NIS-AUTO .12 Annex A (informative) Rationale for requirements. Annex B (informative) Example of a test method for dose accuracy at intended injection depth .14 .16 Annex C (informative) Needle extension and intended injection depth Bibliography .22 @ IS0 2022 - All rights reserved iii

.pdf文档 ISO 11608-5 2022 Needle-based injection systems for medical use Requirements and test methods Part 5 Automated functions

文档预览
中文文档 30 页 50 下载 1000 浏览 0 评论 309 收藏 3.0分
温馨提示:本文档共30页,可预览 3 页,如浏览全部内容或当前文档出现乱码,可开通会员下载原始文档
ISO 11608-5 2022 Needle-based injection systems for medical use  Requirements and test methods  Part 5 Automated functions 第 1 页 ISO 11608-5 2022 Needle-based injection systems for medical use  Requirements and test methods  Part 5 Automated functions 第 2 页 ISO 11608-5 2022 Needle-based injection systems for medical use  Requirements and test methods  Part 5 Automated functions 第 3 页
下载文档到电脑,方便使用
本文档由 人生无常 于 2025-03-25 00:25:09上传分享
友情链接
站内资源均来自网友分享或网络收集整理,若无意中侵犯到您的权利,敬请联系我们微信(点击查看客服),我们将及时删除相关资源。